Medium Resolution Imaging
Spectrometer (MERIS)
MERIS |
Medium Resolution Imaging Spectrometer |
Satellite |
Envisat |
Status (Sept 2006) |
Operational – Utilised in the period 2002 to ~ 2010 |
Mission |
Ocean colour, vegetation, aerosol, cloud properties |
Instrument type |
15-channel VIS/NIR spectro-radiometer, channel positions and bandwidths selectable |
Scanning technique |
Bushbroom, 3700 pixel/line (split in 5 parallel optical systems), total swath 1150 km |
Coverage/cycle |
Global coverage in 3 days, in daylight |
Resolution (s.s.p.) |
Basic IFOV 300 m, reduced resolution for global data recording: 1200 km |
Resources |
Mass: 200 kg - Power: 175 W - Data rate: 24 Mbps |
Central wavelength |
Bandwidth |
Radiometric accuracy (SNR @ specified input radiance) |
412.5 nm |
10 nm |
................. @ ................. |
442.5 nm |
10 nm |
................. @ ................. |
490 nm |
10 nm |
................. @ ................. |
510 nm |
10 nm |
................. @ ................. |
560 nm |
10 nm |
................. @ ................. |
620 nm |
10 nm |
................. @ ................. |
665 nm |
10 nm |
................. @ ................. |
681.25 nm |
7.5 nm |
................. @ ................. |
708.75 nm |
10 nm |
................. @ ................. |
753.75 nm |
7.5 nm |
................. @ ................. |
760.625 nm |
3.75 nm |
................. @ ................. |
778.75 nm |
15 nm |
................. @ ................. |
865 nm |
20 nm |
................. @ ................. |
885 nm |
10 nm |
................. @ ................. |
900 nm |
10 nm |
................. @ ................. |